Mercury 1000 Dual Fuel User's Guide Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
29
9. Technical Data
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Electric 230 / 400 V 50 Hz
Dimensions
Overall height minimum 920 mm maximum 945 mm
Overall width 990 mm
Overall depth 638 mm to front of fascia; 700 mm over handles
Minimum height above cooker 800 mm
Refer to 'Positioning the Cooker'.
Ratings
Max: 1.85 kW
Boost: 3.0 kW
Max: 1.85 kW
Boost: 3.0 kW
Max: 2.3 kW
Boost: 3.7 kW
Max: 1.85 kW
Boost: 3.0 kW
Max: 1.4 kW
Boost: 2.2 kW
Element/Oven Left-hand Multi-function Right-hand Fan
Fan element 2.5 kW 2.5 kW
Top element 1.2 kW
Browning element 1.15 kW
Base element 1.0 kW
Ovens Multi-function Forced Air Convection
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load 0.95 kWh 0.90 kWh
Usable volume (litres) 78 78
Size Large Large
Time to cook standard load 41 minutes 49 minutes
Surface area of the grid 1400 cm
2
790 cm
2
Grill 2.3 kW
Maximum total electrical load at 230 V (approximate total including oven fan, etc.): 18.5 kW.
DocNo.103-0014 - Technical data - IN 1200 - Mercury
Page view 32
1 2 ... 28 29 30 31 32 33 34 35 36

Comments to this Manuals

No comments