90-898303
4-24
Air Temperature Sensor
The air temperature sensor is mounted on top of the air plenum. The ECM
regulates fuel flow, in part, based on manifold air temperature. As air
temperature increases, the ECM decreases fuel flow. Should the air
temperature sensor fail, the ECM will default to a temperature value of 32 °F
(0 °C).
a) Air Temperature Sensor
DDT TEST
1. Set the DDT’s data monitor to read air temp. Refer to the Digital Diagnostic
Terminal Technician Reference Manual for instructions.
2. If the sensor reading appears to be incorrect or invalid, perform a resistance
test on the suspected sensor.
NOTE: Refer to appropriate service manual for test procedure and
specifications.